Product Model: ET1BS12712S0
Retail Price: US$6,871.00
Email Us To Get Special Price Today: [email protected]
ET1BS12712S0 is the Huawei S12712 Switch assembly chassis, including 12 slots.
Quick Specs
Figure 1 shows the S12712 appearance. ET1BS12712S0 is its assembly chassis, including no cards, modules or units.
Table 1 shows the Quick Specs.
Product Code |
ET1BS12712S0 |
Packet Forwarding Rates |
9,120 Mpps; 12,960 Mpps(With Necessary Plug-ins) |
Switching Capacity |
17.44 Tbit/s; 44.96 Tbit/s(With Necessary Plug-ins) |
MPU Slots |
2 |
SFU Slots |
4 |
Service Card Slots |
12 |
Energy Saving |
Energy Efficient Ethernet (802.3az) |
Redundancy Design |
MPUs, SFUs, power supplies, and fan modules |
Maximum Power Consumption of the Entire Equipment |
¡Ü 6,600W |
Dimensions (W x D x H) |
With cable management frames: 442 mm x 585 mm x 841.75 mm (17.4 in. x 23.0 in. x 33.1 in. (19 U)) Without cable management frames: 442 mm x 489 mm x 841.75 mm (17.4 in. x 19.3 in. x 33.1 in. (19 U)) |
Weight |
63 kg |
Product Details
Figure 2 shows the front structure of the?ET1BS12712S0.
Note:
¢Ù |
Two MPUs |
¢Ú |
Twelve service cards, including: ¡¤Open Service Platform Unit |
¢Û |
Four SFUs |
¢Ü |
A pair of mounting brackets |
¢Ý |
Six power modules |
¢Þ |
Two CMUs |
¢ß |
Front ESD jack |
¢à |
Cable management frames |
¡¤The ET1BS12712S0 is just a Chassis that it doesn’t provide cards, modules or units. The cards, modules or units must be purchased separately.
¡¤The mounting brackets are used to secure the chassis in a cabinet.
¡¤The ground terminal of an ESD wrist strap can be inserted in this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.
¡¤The cable management frames separate cables on different cards and help route cables orderly.
Figure 3 shows the rear structure of the ET1BS12712S0.
Note:
¢Ù |
Five Fan Modules |
¢Ú |
Rear ESD jack |
¢Û |
JG ground terminal |
¢Ü |
A pair of handles |
¢Ý |
Air filter |
¡¤The ground terminal of an ESD wrist strap can be inserted in this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.
¡¤The handles are only used for this purpose: After you lift the chassis onto the guide rails or tray, grasp the handles to drag the chassis into the cabinet.
¡¤The air filter prevents dust from entering the chassis.
The Modules, Cards
Table 2 shows the recommended elements for the ET1BS12712S0.
Model |
Description |
FE-SFP optical transceiver |
|
SFP-FE-SX-MM1310 |
Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC) |
eSFP-FE-LX-SM1310 |
Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC) |
S-SFP-FE-LH40-SM1310 |
Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC) |
GE-SFP optical transceiver |
|
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
10G-SFP+ optical transceiver |
|
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
OMXD30000 |
Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
OSX010000 |
Optical Transceiver, SFP+, 10G, Single-mode Module(1310nm, 10km, LC) |
40GE CFP optical transceiver |
|
CFP-40G-SR4 |
High Speed Transceiver CFP-40G-SR4,CFP,40G,Multimode Module(850nm,4*10G,0.1km,MPO) |
CFP-40G-LR4 |
High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,10km,stright LC) |
CFP-40G-ER4 ? |
High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,40km,stright LC) |
40GE QSFP+ optical transceiver |
|
QSFP-40G-eSR4 ? |
40GBase-eSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.3km,MPO)(Connect to four SFP+ Optical Transceiver) |
QSFP-40G-ER4 ? |
40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC) |
100GE CFP optical transceiver |
|
CFP-100G-SR10 ? |
High Speed Transceiver,CFP,100G,Multimode Module(850nm,10*10G,0.1km,MPO) |
CFP-100G-LR4 ? |
CFP, 100G, Single-mode Module(1310nm band,4*25G,10km,stright LC) |
CFP-100G-ER4 ? |
High Speed Transceiver,CFP,100G,Single-mode Module(1310nm band,4*25G,40km,stright LC) |
GE copper transceiver |
|
SFP-1000BaseT |
Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
100GE interface card |
|
ET1D2C02FEE0 ? |
2-Port 100GBASE-X Interface Card(EE,CFP) ET1D2C02FEE0series) |
10GE interface card |
|
ET1D2X32SSC0 ? |
32-Port 10GBASE-X Interface Card(SC,SFP+) |
ET1D2X12SSA0 ? |
12-Port 10GBASE-X Interface Card(SA,SFP+) |
40GE interface card |
|
ET1D2L08QSC0 ? |
8-Port 40GBASE-X Interface Card(SC,QSFP+) |
ET1D2L02QSC0 ? |
2-Port 40GBASE-X Interface Card(SC,QSFP+) |
Centralized monitoring unit |
|
EH1D200CMU00 ? |
Centralized Monitoring Board |
Cluster switching system unit |
|
EH1D2VS08000 ? |
8-Port 10G Cluster Switching System Service Unit (SFP+) |
Firewall module |
|
ET1D2FW00S02 ? |
NGFW Module C,with HW General Security Platform Software |
ET1D2FW00S01 ? |
NGFW Module B,with HW General Security Platform Software |
GE/10GE interface card |
|
ET1D2S08SX1E ? |
8-Port 10GBASE-X and 8-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+) |
ET1D2S04SX1E ? |
4-Port 10GBASE-X and 24-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+) |
Intrusion prevention system module |
|
ET1D2IPS0S00 ? |
IPS Module A,with HW General Security Platform Software |
Main processing unit |
|
ET1D2MPUA000 ? |
S12708/S12712,Main Processing Unit A(Optional clock) |
Switch fabric unit |
|
ET1D2SFUD000 ? |
S12708/S12712,Switch Fabric Unit D |
ET1D2SFUA000 ? |
S12708/S12712,Switch Fabric Unit A |
Wireless access controller unit |
|
ACU2 ? |
WLAN?ACU2?Access Controller Unit(128 AP Control Resource Included) |
GE interface card |
|
ET1D2T36SEA0 ? |
36-Port 10/100/1000BASE-T and 12-Port 100/1000BASE-X Interface Card(EA,RJ45/SFP) |
ET1D2G48SX1E ? |
48-Port 100/1000BASE-X Interface Card(X1E,SFP) |
Compare to Similar Items
Table 3 shows the comparison of ET1BS12712S0 and ET1BS12708S0.
Product Code |
ET1BS12712S0 |
ET1BS12708S0 |
Description |
Huawei S12712 Switch assembly chassis |
Huawei S12708 Switch assembly chassis |
Packet Forwarding Rates |
9,120 Mpps; 12,960 Mpps(With Necessary Plug-ins) |
6,240 Mpps; 9,120 Mpps(With Necessary Plug-ins) |
Switching Capacity |
17.44 Tbit/s; 44.96 Tbit/s(With Necessary Plug-ins) |
12.32 Tbit/s; 32.16 Tbit/s(With Necessary Plug-ins) |
MPU Slots |
2 |
2 |
SFU Slots |
4 |
4 |
Service Card Slots |
12 |
8 |
Maximum Power Consumption of the Entire Equipment |
¡Ü 6,600W |
¡Ü 4,400W |
Weight |
63 kg |
42 kg |
Before Purchasing
Do you have any?question about?the?ET1BS12712S0
Contact us – Email Live Chat or [email protected].
ET1BS12712S0 Datasheet
ET1BS12712S0 Specification |
|
Switching Capacity |
17.44 Tbit/s; 44.96 Tbit/s |
Packet Forwarding Rates |
9,120 Mpps; 12,960 Mpps |
MPU Slots |
2 |
SFU Slots |
4 |
Service Card Slots |
12 |
Redundancy Design |
MPUs, SFUs, power supplies, and fan modules |
CSS2 |
1+N backup of MPUs in a cluster |
Up to 1.92 Tbit/s cluster bandwidth, 4 μs inter-chassis transmission latency |
|
Wireless Network Management |
Native AC |
AP access control, AP region management, and AP profile management |
|
Radio profile management, uniform static configuration, and centralized dynamic management |
|
Basic WLAN services, QoS, security, and user management |
|
User Management |
Unified user management |
802.1x, MAC, and Portal authentication |
|
Traffic- and time-based accounting |
|
User authorization based on user groups, domains, and time ranges |
|
iPCA Quality Awareness |
Marking real service packets to obtain real-time count of dropped packets and packet loss ratio |
Counting number of dropped packets and packet loss ratio on devices and L2/L3 networks |
|
SVF2.0 Virtualization |
Up to 4K clients (access switches and APs) virtualized into a single device |
Two layers of ASs allowed in an SVF system |
|
Third-party devices allowed between SVF parent and clients |
|
VLAN |
Access, trunk, and hybrid interface types, auto-negotiation of LNP links |
Default VLAN |
|
VLAN switching |
|
QinQ and selective QinQ |
|
MAC address-based VLAN assignment |
|
ARP |
256K ARP entries |
MAC Address |
1M MAC address entries |
Dynamic MAC address learning and aging |
|
Static, dynamic, and blackhole MAC address entries |
|
Source MAC address filtering |
|
MAC address limiting based on ports and VLANs |
|
Ring Network Protection |
Spanning Tree Protocol (STP) (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
SEP |
|
Bridge Protocol Data Unit (BPDU), root protection, and loop protection |
|
BPDU tunnel |
|
G.8032 Ethernet Ring Protection Switching (ERPS) |
|
IP Routing |
3M IPv4 routing entries |
512K IPv6 routing entries |
|
IPv4 dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP |
|
IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+ |
|
Multicast |
128,000 multicast routing entries |
IGMP v1/v2/v3 and IGMP v1/v2/v3 snooping |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
Multicast Source Discovery Protocol (MSDP) and Multiprotocol Extensions for BGP (MBGP) |
|
Fast leave |
|
Multicast traffic control |
|
Multicast querier |
|
Multicast protocol packet suppression |
|
Multicast Call Admission Control (CAC) |
|
Multicast ACL |
|
MPLS |
Basic MPLS functions |
MPLS Operations, Administration, and Maintenance (OAM) |
|
MPLS Traffic Engineering (TE) |
|
MPLS VPN/VLL/VPLS |
|
Reliability |
Link Aggregation Control Protocol (LACP) and E-Trunk |
Virtual Router Redundancy Protocol (VRRP) and Bi-directional Forwarding Detection (BFD) for VRRP |
|
BFD for BGP/IS-IS/OSPF/static route |
|
Non-Stop Routing (NSR), Non-Stop Forwarding (NSF) and Graceful Restart (GR) for BGP/IS-IS/OSPF/LDP |
|
TE Fast ReRoute (FRR) and IP FRR |
|
Eth-OAM 802.3ah and 802.1ag (hardware-based) |
|
HSR |
|
ITU-Y.1731 |
|
Device Link Detection Protocol (DLDP) |
|
QoS |
256K ACLs |
Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority |
|
ACLs and actions such as Committed Access Rate (CAR), re-marking, and scheduling |
|
Queuing algorithms, such as SP, WRR, DRR, SP + WRR, and SP + DRR |
|
Congestion avoidance mechanisms, including (WRED) and tail drop |
|
H-QoS |
|
Traffic shaping |
|
Network Synchronization |
Ethernet synchronization |
1588v2 |
|
Configuration and Maintenance |
Terminal access services such as console port login, Telnet, and SSH |
Network management protocols, such as SNMP v1/v2/v3 |
|
File uploading and downloading through FTP and TFTP |
|
BootROM upgrade and remote in-service upgrade |
|
Hot patches |
|
User operation logs |
|
Security and Management |
MAC address, Portal, 802.1x, and Dynamic Host Configuration Protocol (DHCP) snooping triggered authentication |
MACsec |
|
RADIUS and HWTACACS authentication for login users |
|
Command line authority control based on user levels, preventing unauthorized users from using command configurations |
|
Defense against DoS attacks, Transmission Control Protocol (TCP) SYN Flood attacks, User Datagram Protocol (UDP) Flood attacks, broadcast storms, and heavy traffic attacks |
|
Remote Network Monitoring (RMON) |
|
Security Protection* |
Firewall |
Network Address Translation (NAT) |
|
IPSec, SSL VPN |
|
Intrusion Protection System (IPS) |
|
Load balancing Analog Digital Conversion (ADC) |
|
Interoperability |
Interoperable with VBST (compatible with PVST/PVST+/RPVST) |
Interoperable with LNP (similar to DTP) |
|
Interoperable with VCMP (similar to VTP) |
|
Energy Saving |
Energy Efficient Ethernet (802.3az) |
Dimensions (H x W x D) |
841.75 mm x 442 mm x 489 mm, 19U |
Weight (empty chassis) |
63 kg |
Operating Voltage |
DC: –40V to –72V AC: 90V to 290V |
Maximum Power Consumption of the Entire Equipment |
≤ 6,600W |