CE12804D-B02 Huawei CE12800 Series Data Center Switch Price & Product Datasheet

Product Model: CE12804D-B02

Retail Price: US$34,523.00

Email Us To Get Special Price Today: [email protected]

CE12804D-B02 is CE12804 DC Bundle2 DC Assembly Chassis, 2*MPUA, 5*SFU04B, 3*PDC-2200WA).

Quick Specs

Figure 1 shows the appearance of CE12804 DC chassis. CE12804D-B02 is it¡¯s assembly chassis.

Table 1 shows the Quick Specs.

Product Code

CE12804D-B02

Switching Capacity?
(Tbit/s)

45/

258

Forwarding Rate?
(Mpps)

17,280

Service Slots

4

Switching Fabric?
Module Slots

6

LPU slots

4 (slot IDs: 01 to 04)

MPU slots

2 (slot IDs: 05 to 06)

CMU slots

2 (slot IDs: 07 to 08)

SFU slots

6 (slot IDs: 09 to 14)

Power slots

4 (slot IDs: PM1 to PM4)

Fan slots

9 (slot IDs: FAN1 to FAN9)

Product Details

Figure 2 shows the front panel of CE12804D-B02.

Note:

¢Ù

Two CMUs

¢Ú

Cable management frame

NOTE:

Cable management frames are installed on the left and right sides of a chassis to route cables in each slot.

¢Û

Front ESD jack

NOTE:

When maintaining components at the front of a chassis, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack.

¢Ü

Power modules

¢Ý

Two MPUs

The CE12804 chassis uses the CE-MPUA.

¢Þ

LPUs

CE12804 chassis: supports 4 LPUs.

* CE12804D-B02 has only DC Assembly Chassis, 2*MPUA, 5*SFU04B and 3*PDC-2200WA, if you need other modules or cards, you must be purchased separately.

Figure 3 shows the back panel of CE12804D-BD2.

¢Ù

Serial number label

¢Ú

Rear ESD jack

?

¢Û

?Handle

¢Ü

Power distribution unit

¢Ý

MAC address label

¢Þ

Fan modules

¢ß

SFU

¢à

Two ground points for a dual-hole ground lug, with a yellow grounding label attached

* CE12804D-B02 has only DC Assembly Chassis, 2*MPUA, 5*SFU04B and 3*PDC-2200WA, if you need other modules or cards, you must be purchased separately.

The Modules, Cards

Table 2 shows the recommended elements for the CE12804D-B02.

Model

Description

AC power module

PAC-2700WA

2700W AC Power Supply

FE-SFP optical transceiver

SFP-FE-SX-MM1310

Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC)

eSFP-FE-LX-SM1310

Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC)

S-SFP-FE-LH40-SM1310

Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC)

GE-SFP optical transceiver

eSFP-GE-SX-MM850

Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC)

SFP-GE-LX-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC)

10G-SFP+ optical transceiver

SFP-10G-USR

10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC)

OMXD30000

Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC)

40GE CFP optical transceiver

CFP-40G-LR4

High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,10km,stright LC)

CFP-40G-ER4

High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,40km,stright LC)

40GE QSFP+ optical transceiver

QSFP-40G-eSR4

40GBase-eSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.3km,MPO)(Connect to four SFP+ Optical Transceiver)

QSFP-40G-ER4

40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC)

100GE CFP optical transceiver

CFP-100G-SR10

High Speed Transceiver,CFP,100G,Multimode Module(850nm,10*10G,0.1km,MPO)

CFP-100G-LR4

CFP, 100G, Single-mode Module(1310nm band,4*25G,10km,stright LC)

CFP-100G-ER4

High Speed Transceiver,CFP,100G,Single-mode Module(1310nm band,4*25G,40km,stright LC)

GE copper transceiver

SFP-1000BaseT

Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45)

100GE interface card

CE-L12CF-EG

12-Port-100GE Interface Card(EG,CFP2)

CE-L08CC-EC

8-Port-100G Interface Card(EC,CXP)

10GE interface card

CE-L48XT-EC

Huawei 48-port 100M/1000M/10G Base-T Interface Card(EC,RJ45) CE-L48XT-EC

CE-L48XS-EC

48-Port-10GE Interface Card(EC,SFP+)

40GE interface card

CE-L24LQ-EC1

24-Port-40G Interface Card(EC1,QSFP+)

CE-L12LQ-EF

12-Port-40G Interface Card(EF,QSFP+)

Firewall module

CE-FWA

Huawei CE12800 NGFW Module A CE-FWA, with HW General Security Platform Software

GE interface card

CE-L48GT-ED

48-Port 10/100/1000BASE-T Interface Card(ED,RJ45)

CE-L48GS-ED

48-Port 100/1000BASE-X Interface Card(ED,SFP)

Compare to Similar Items

Table 3 shows the comparison of CE12804D-B02 and CE12804S-DC.

Product Code

CE12804D-B02

CE12804S-DC

Switching Capacity?
(Tbit/s)

45/

258

45/

258

Forwarding Rate?
(Mpps)

17,280

17,280

Service Slots

4

4

Switching Fabric?
Module Slots

6

2

LPU slots

4 (slot IDs: 01 to 04)

4 (slot IDs: 01 to 04)

MPU slots

2 (slot IDs: 05 to 06)

2 (slot IDs: 05 to 06)

CMU slots

2 (slot IDs: 07 to 08)

None (monitoring function integrated on the MPU)

SFU slots

6 (slot IDs: 09 to 14)

2 (slot IDs: 07 to 08)

Power slots

4 (slot IDs: PM1 to PM4)

4 (slot IDs: PM1 to PM4)

Fan slots

9 (slot IDs: FAN1 to FAN9)

3 (slot IDs: FAN1 to FAN3)

Before Purchasing

Do you have any?question about?the?CE12804D-B02

Contact us – Email Live Chat or [email protected].

Specification

CE12804D-B02 Datasheet

CE12804D-B02 Specifications

Switching Capacity 
(Tbit/s)

45/
2581

Forwarding Rate 
(Mpps)

17,280

Service Slots

4

Switching Fabric 
Module Slots

6

Fabric Architecture

Clos architecture, cell switching, VoQ, and distributed large buffer

Airflow Design

Strict front-to-back

Device Virtualization

Virtual System (VS)

Cluster Switch System (CSS)2

Super Virtual Fabric (SVF)3

Network Virtualization

M-LAG

TRILL

VxLAN routing and bridging

EVPN

QinQ in VXLAN

VM Awareness

Agile Controller

Network Convergence

FCoE

DCBX, PFC, and ETS

Data Center Interconnect

BGP-EVPN

Ethernet Virtual Network (EVN) for inter-DC Layer 2 network interconnections

Programmability

OpenFlow

ENP programming

OPS programming

Puppet, Ansible, and OVSDB plug-ins released on open source websites

Linux container for open source and customization programming

Traffic Analysis

NetStream

Hardware-based sFlow

VLAN

Adding access, trunk, and hybrid interfaces to VLANs

Default VLAN

QinQ

MUX VLAN

GVRP

MAC Address

Dynamic learning and aging of MAC addresses

Static, dynamic, and blackhole MAC address entries

Packet filtering based on source MAC addresses

MAC address limiting based on ports and VLANs

IP Routing

IPv4 routing protocols, such as RIP, OSPF, IS-IS, and BGP

IPv6 routing protocols, such as RIPng, OSPFv3, ISISv6, and BGP4+

IP packet fragmentation and reassembling

IPv6

IPv6 over VXLAN

IPv6 over IPv4

IPv6 Neighbor Discovery (ND)

Path MTU Discovery (PMTU)

TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6

Multicast

IGMP, PIM-SM, PIM-DM, MSDP, and MBGP

IGMP snooping

IGMP proxy

Fast leave of multicast member interfaces

Multicast traffic suppression

Multicast VLAN

MPLS

Basic MPLS functions

MPLS VPN/VPLS/VPLS over GRE

Reliability

Link Aggregation Control Protocol (LACP)

STP, RSTP, VBST, and MSTP

BPDU protection, root protection, and loop protection

Smart Link and multi-instance

Device Link Detection Protocol (DLDP)

Ethernet Ring Protection Switching (ERPS, G.8032)

Hardware-based Bi-directional Forwarding Detection (BFD)

VRRP, VRRP load balancing, and BFD for VRRP

BFD for BGP/IS-IS/OSPF/Static route

In-Service Software Upgrade (ISSU)

Segment Routing (SR)

QoS

Traffic classification based on Layer 2, Layer 3, Layer 4, and priority information

Actions include ACL, CAR, and re-marking

Queue scheduling modes such as PQ, WFQ, and PQ + WRR

Congestion avoidance mechanisms, including WRED and tail drop

Traffic shaping

O&M

IEEE 1588v2

Packet Conservation Algorithm for Internet (iPCA)

Dynamic Load Balancing (DLB)

Dynamic Packet Prioritization (DPP)

Network-wide path detection

Microsecond-level buffer detection

Configuration 
and Maintenance

Console, Telnet, and SSH terminals

Network management protocols, such as SNMPv1/v2c/v3

File upload and download through FTP and TFTP

BootROM upgrade and remote upgrade

Hot patches

User operation logs

Zero-Touch Provisioning (ZTP)

Security 
and Management

802.1x authentication

RADIUS and HWTACACS authentication for login users

Command line authority control based on user levels, preventing unauthorized users from using commands

Defense against MAC address attacks, broadcast storms, and heavy-traffic attacks

Ping and traceroute

Remote Network Monitoring (RMON)

Dimensions 
(W x D x H, mm)

442 x 
813 x 
486.15 
(11 U)

Chassis Weight (empty)

< 110 kg
(242 lb)

Operating Voltage

AC: 90V to 290V
DC: -38.4V to -72V
HVDC: 240V

Max. Power Supply

6,000W

Leave a Comment

Your email address will not be published. Required fields are marked *

Call Us Now
Scroll to Top

Warning: error_log(/www/wwwroot/corenet.vip/wp-content/plugins/spider-analyser/#log/log-1723.txt): Failed to open stream: Permission denied in /www/wwwroot/corenet.vip/wp-content/plugins/spider-analyser/spider.class.php on line 2853