ET1BS12712S0 S12700 Series Switch Chassis Price & Product Datasheet

Product Model: ET1BS12712S0

Retail Price: US$6,871.00

Email Us To Get Special Price Today: [email protected]

ET1BS12712S0 is the Huawei S12712 Switch assembly chassis, including 12 slots.

Quick Specs

Figure 1 shows the S12712 appearance. ET1BS12712S0 is its assembly chassis, including no cards, modules or units.

Table 1 shows the Quick Specs.

Product Code

ET1BS12712S0

Packet Forwarding Rates

9,120 Mpps; 12,960 Mpps(With Necessary Plug-ins)

Switching Capacity

17.44 Tbit/s; 44.96 Tbit/s(With Necessary Plug-ins)

MPU Slots

2

SFU Slots

4

Service Card Slots

12

Energy Saving

Energy Efficient Ethernet (802.3az)

Redundancy Design

MPUs, SFUs, power supplies, and fan modules

Maximum Power Consumption of the Entire Equipment

¡Ü 6,600W

Dimensions (W x D x H)

With cable management frames: 442 mm x 585 mm x 841.75 mm (17.4 in. x 23.0 in. x 33.1 in. (19 U))

Without cable management frames: 442 mm x 489 mm x 841.75 mm (17.4 in. x 19.3 in. x 33.1 in. (19 U))

Weight

63 kg

Product Details

Figure 2 shows the front structure of the?ET1BS12712S0.

Note:

¢Ù

Two MPUs

¢Ú

Twelve service cards, including:

¡¤Open Service Platform Unit
¡¤1000M Interface Card
¡¤GE/10GE Interface Card
¡¤10GE Interface Card
¡¤40GE Interface Card
¡¤100GE Interface Card

¢Û

Four SFUs

¢Ü

A pair of mounting brackets

¢Ý

Six power modules

¢Þ

Two CMUs

¢ß

Front ESD jack

¢à

Cable management frames

¡¤The ET1BS12712S0 is just a Chassis that it doesn’t provide cards, modules or units. The cards, modules or units must be purchased separately.
¡¤The mounting brackets are used to secure the chassis in a cabinet.
¡¤The ground terminal of an ESD wrist strap can be inserted in this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.
¡¤The cable management frames separate cables on different cards and help route cables orderly.

Figure 3 shows the rear structure of the ET1BS12712S0.

Note:

¢Ù

Five Fan Modules

¢Ú

Rear ESD jack

¢Û

JG ground terminal

¢Ü

A pair of handles

¢Ý

Air filter

¡¤The ground terminal of an ESD wrist strap can be inserted in this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.
¡¤The handles are only used for this purpose: After you lift the chassis onto the guide rails or tray, grasp the handles to drag the chassis into the cabinet.
¡¤The air filter prevents dust from entering the chassis.

The Modules, Cards

Table 2 shows the recommended elements for the ET1BS12712S0.

Model

Description

FE-SFP optical transceiver

SFP-FE-SX-MM1310

Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC)

eSFP-FE-LX-SM1310

Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC)

S-SFP-FE-LH40-SM1310

Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC)

GE-SFP optical transceiver

eSFP-GE-SX-MM850

Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC)

SFP-GE-LX-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC)

10G-SFP+ optical transceiver

SFP-10G-USR

10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC)

OMXD30000

Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC)

OSX010000

Optical Transceiver, SFP+, 10G, Single-mode Module(1310nm, 10km, LC)

40GE CFP optical transceiver

CFP-40G-SR4

High Speed Transceiver CFP-40G-SR4,CFP,40G,Multimode Module(850nm,4*10G,0.1km,MPO)

CFP-40G-LR4

High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,10km,stright LC)

CFP-40G-ER4

?

High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,40km,stright LC)

40GE QSFP+ optical transceiver

QSFP-40G-eSR4

?

40GBase-eSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.3km,MPO)(Connect to four SFP+ Optical Transceiver)

QSFP-40G-ER4

?

40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC)

100GE CFP optical transceiver

CFP-100G-SR10

?

High Speed Transceiver,CFP,100G,Multimode Module(850nm,10*10G,0.1km,MPO)

CFP-100G-LR4

?

CFP, 100G, Single-mode Module(1310nm band,4*25G,10km,stright LC)

CFP-100G-ER4

?

High Speed Transceiver,CFP,100G,Single-mode Module(1310nm band,4*25G,40km,stright LC)

GE copper transceiver

SFP-1000BaseT

Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45)

100GE interface card

ET1D2C02FEE0

?

2-Port 100GBASE-X Interface Card(EE,CFP) ET1D2C02FEE0series)

10GE interface card

ET1D2X32SSC0

?

32-Port 10GBASE-X Interface Card(SC,SFP+)

ET1D2X12SSA0

?

12-Port 10GBASE-X Interface Card(SA,SFP+)

40GE interface card

ET1D2L08QSC0

?

8-Port 40GBASE-X Interface Card(SC,QSFP+)

ET1D2L02QSC0

?

2-Port 40GBASE-X Interface Card(SC,QSFP+)

Centralized monitoring unit

EH1D200CMU00

?

Centralized Monitoring Board

Cluster switching system unit

EH1D2VS08000

?

8-Port 10G Cluster Switching System Service Unit (SFP+)

Firewall module

ET1D2FW00S02

?

NGFW Module C,with HW General Security Platform Software

ET1D2FW00S01

?

NGFW Module B,with HW General Security Platform Software

GE/10GE interface card

ET1D2S08SX1E

?

8-Port 10GBASE-X and 8-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+)

ET1D2S04SX1E

?

4-Port 10GBASE-X and 24-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+)

Intrusion prevention system module

ET1D2IPS0S00

?

IPS Module A,with HW General Security Platform Software

Main processing unit

ET1D2MPUA000

?

S12708/S12712,Main Processing Unit A(Optional clock)

Switch fabric unit

ET1D2SFUD000

?

S12708/S12712,Switch Fabric Unit D

ET1D2SFUA000

?

S12708/S12712,Switch Fabric Unit A

Wireless access controller unit

ACU2

?

WLAN?ACU2?Access Controller Unit(128 AP Control Resource Included)

GE interface card

ET1D2T36SEA0

?

36-Port 10/100/1000BASE-T and 12-Port 100/1000BASE-X Interface Card(EA,RJ45/SFP)

ET1D2G48SX1E

?

48-Port 100/1000BASE-X Interface Card(X1E,SFP)

Compare to Similar Items

Table 3 shows the comparison of ET1BS12712S0 and ET1BS12708S0.

Product Code

ET1BS12712S0

ET1BS12708S0

Description

Huawei S12712 Switch assembly chassis

Huawei S12708 Switch assembly chassis

Packet Forwarding Rates

9,120 Mpps; 12,960 Mpps(With Necessary Plug-ins)

6,240 Mpps; 9,120 Mpps(With Necessary Plug-ins)

Switching Capacity

17.44 Tbit/s; 44.96 Tbit/s(With Necessary Plug-ins)

12.32 Tbit/s; 32.16 Tbit/s(With Necessary Plug-ins)

MPU Slots

2

2

SFU Slots

4

4

Service Card Slots

12

8

Maximum Power Consumption of the Entire Equipment

¡Ü 6,600W

¡Ü 4,400W

Weight

63 kg

42 kg

Before Purchasing

Do you have any?question about?the?ET1BS12712S0

Contact us – Email Live Chat or [email protected].

Specification

ET1BS12712S0 Datasheet

ET1BS12712S0 Specification

Switching Capacity

17.44 Tbit/s; 44.96 Tbit/s

Packet Forwarding Rates

9,120 Mpps; 12,960 Mpps

MPU Slots

2

SFU Slots

4

Service Card Slots

12

Redundancy Design

MPUs, SFUs, power supplies, and fan modules

CSS2

1+N backup of MPUs in a cluster

Up to 1.92 Tbit/s cluster bandwidth, 4 μs inter-chassis transmission latency

Wireless Network Management

Native AC

AP access control, AP region management, and AP profile management

Radio profile management, uniform static configuration, and centralized dynamic management

Basic WLAN services, QoS, security, and user management

User Management

Unified user management

802.1x, MAC, and Portal authentication

Traffic- and time-based accounting

User authorization based on user groups, domains, and time ranges

iPCA Quality Awareness

Marking real service packets to obtain real-time count of dropped packets and packet loss ratio

Counting number of dropped packets and packet loss ratio on devices and L2/L3 networks

SVF2.0 Virtualization

Up to 4K clients (access switches and APs) virtualized into a single device

Two layers of ASs allowed in an SVF system

Third-party devices allowed between SVF parent and clients

VLAN

Access, trunk, and hybrid interface types, auto-negotiation of LNP links

Default VLAN

VLAN switching

QinQ and selective QinQ

MAC address-based VLAN assignment

ARP

256K ARP entries

MAC Address

1M MAC address entries

Dynamic MAC address learning and aging

Static, dynamic, and blackhole MAC address entries

Source MAC address filtering

MAC address limiting based on ports and VLANs

Ring Network Protection

Spanning Tree Protocol (STP) (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)

SEP

Bridge Protocol Data Unit (BPDU), root protection, and loop protection

BPDU tunnel

G.8032 Ethernet Ring Protection Switching (ERPS)

IP Routing

3M IPv4 routing entries

512K IPv6 routing entries

IPv4 dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP

IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+

Multicast

128,000 multicast routing entries

IGMP v1/v2/v3 and IGMP v1/v2/v3 snooping

PIM-DM, PIM-SM, and PIM-SSM

Multicast Source Discovery Protocol (MSDP) and Multiprotocol Extensions for BGP (MBGP)

Fast leave

Multicast traffic control

Multicast querier

Multicast protocol packet suppression

Multicast Call Admission Control (CAC)

Multicast ACL

MPLS

Basic MPLS functions

MPLS Operations, Administration, and Maintenance (OAM)

MPLS Traffic Engineering (TE)

MPLS VPN/VLL/VPLS

Reliability

Link Aggregation Control Protocol (LACP) and E-Trunk

Virtual Router Redundancy Protocol (VRRP) and Bi-directional Forwarding Detection (BFD) for VRRP

BFD for BGP/IS-IS/OSPF/static route

Non-Stop Routing (NSR), Non-Stop Forwarding (NSF) and Graceful Restart (GR) for BGP/IS-IS/OSPF/LDP

TE Fast ReRoute (FRR) and IP FRR

Eth-OAM 802.3ah and 802.1ag (hardware-based)

HSR

ITU-Y.1731

Device Link Detection Protocol (DLDP)

QoS

256K ACLs

Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority

ACLs and actions such as Committed Access Rate (CAR), re-marking, and scheduling

Queuing algorithms, such as SP, WRR, DRR, SP + WRR, and SP + DRR

Congestion avoidance mechanisms, including (WRED) and tail drop

H-QoS

Traffic shaping

Network Synchronization

Ethernet synchronization

1588v2

Configuration and Maintenance

Terminal access services such as console port login, Telnet, and SSH

Network management protocols, such as SNMP v1/v2/v3

File uploading and downloading through FTP and TFTP

BootROM upgrade and remote in-service upgrade

Hot patches

User operation logs

Security and Management

MAC address, Portal, 802.1x, and Dynamic Host Configuration Protocol (DHCP) snooping triggered authentication

MACsec

RADIUS and HWTACACS authentication for login users

Command line authority control based on user levels, preventing unauthorized users from using command configurations

Defense against DoS attacks, Transmission Control Protocol (TCP) SYN Flood attacks, User Datagram Protocol (UDP) Flood attacks, broadcast storms, and heavy traffic attacks

Remote Network Monitoring (RMON)

Security Protection*

Firewall

Network Address Translation (NAT)

IPSec, SSL VPN

Intrusion Protection System (IPS)

Load balancing Analog Digital Conversion (ADC)

Interoperability

Interoperable with VBST (compatible with PVST/PVST+/RPVST)

Interoperable with LNP (similar to DTP)

Interoperable with VCMP (similar to VTP)

Energy Saving

Energy Efficient Ethernet (802.3az)

Dimensions (H x W x D)

841.75 mm x 442 mm x 489 mm, 19U

Weight (empty chassis)

63 kg

Operating Voltage

DC: –40V to –72V

AC: 90V to 290V

Maximum Power Consumption of the Entire Equipment

≤ 6,600W