Cisco ASR-920-24SZ-M Price & Datasheet

Product Model: ASR-920-24SZ-M

Retail Price: US$2,807.00

Email Us To Get Special Price Now: [email protected]

Cisco ASR-920-24SZ-M is part of the Cisco ASR920 Series, offering 24GE Fiber and 4-10GE ports with a modular PSU. This high-performance router is perfect for service providers and large enterprises, providing robust connectivity and flexible deployment options.

Product Highlights

  • ● 24GE Fiber ports
  • ● 4-10GE ports
  • ● Modular PSU
  • ● Carrier-class reliability
  • ● Flexible deployment

Product Features Comparison

Model Ethernet Ports 10GE Ports PSU Type Backplane Capacity Redundancy Operating Temperature
ASR-920-24SZ-M 24 1GE 4 Modular 240 Gbps Yes -40°C to 65°C
ASR-920-4SZ-D 4 1GE 2 Fixed 120 Gbps No -40°C to 65°C
ASR-920-12CZ-A 12 1GE 8 Modular 240 Gbps Yes -40°C to 65°C
ASR-920-8S4Z-PD 8 1GE 4 Fixed 120 Gbps No -40°C to 65°C
ASR-920-24TZ-M 24 1GE 4 Modular 240 Gbps Yes -40°C to 65°C
ASR-920-10SZ-IM 10 1GE 2 Modular 120 Gbps No -40°C to 65°C

Product Application Scenarios

  • ● Service provider edge
  • ● Enterprise connectivity
  • ● High-capacity switch aggregation

Optional Add-ons

Model Description
800-38101-01 AC Power Supply Module
800-38103-01 DC Power Supply Module
MEM-920-4G 4GB Memory Upgrade

Get More Information

Discover unbeatable prices and fast shipping for the Cisco ASR-920-24SZ-M. Access the detailed ASR-920-24SZ-M datasheet and ensure you’re getting the best deal with our reliable delivery service. Need assistance? Our free live chat support is here to help. For more information about the product and pricing, contact us via live chat or email us at [email protected].

Specification

ASR-920-24SZ-M Datasheet

ASR-920-24SZ-M Specifications

Physical specifications1

(H x W x D)

1.72 x 17.5 x 10 in. (43.7 x 444.5 x 255 mm), 1RU
Weight 8.5 lb (3.9kg) – empty chassis
Rack mounts

ETSI rack-mount kit

19-in. rack-mount kit

23-in. rack-mount kit

Air flow Front-to-Back & Side-to-Back airflow
Power supplies 546,260
Mean time between failures (MTBF) (hours)  
1 Measured from the front of the chassis (excluding handles from the power supply, fan tray, and interface modules installed in the chassis).
Power consumption Max 145W, Typical: 110W
AC input voltage and frequency

Voltage range: 85V AC to 264V AC, nominal 100V AC to 240V AC

Frequency Range: 47 to 63 Hz, nominal 50 to 60 Hz

DC input voltage Voltage range: -18 to -32 VDC or -36 to -72 VDC, nominal: -24 VDC/-48 VDC
Operating environment and altitude1

-40 to 70ºC, up to 1,000 feet (300m)

-40 to 65ºC, up to 6,000 feet (1800m)

-40 to 55ºC, up to 13,000 feet (4000m)

Relative humidity 5 to 95 percent, noncondensing
Acoustic noise2 Acoustic noise peak operation compliant to the Network Equipment Building Standards (NEBS) GR-63-Core Issue 3 sound power level of 78 dB at 27ºC operation as measured by the ANSI S12.10/ISO 7779 NAIS noise measurement test standard.
Storage environment Temperature: -40 to 70ºC altitude: 15,000 feet (4570m)
Seismic Zone 4
Safety ●  UL 60950-1, 2005
●  CAN/CSA C22.2 No. 60950-1: 2005
●  IEC 60950-1, 2005
●  EN 60950-1, 2005
●  AS/NZS 60950.1:2005

Electromagnetic

●  FCC CFR47 Part 15 Class A
Emissions compliance ●  EN55022, class A
●  CISPR22, class A
●  ICES-003, class A
●  EN 300 386, class A
●  VCCI, class A
●  KN22, class A
●  EN61000-3-2 to EN61000-3-3
Immunity compliance ●  EN 300 386
●  EN 61000-6-1
●  EN 50082-1
●  CISPR24
●  EN 55024
●  KN 24
●  EN 50121-4
●  EN/KN 61000-4-2 to EN/KN 61000-4-6
●  EN/KN 61000-4-8
●  EN/KN 61000-4-11
Power substation system compliance ●  IEC-61850-3 (2002) (ASR-920-12SZ-IM)
●  IEEE1613 (2009) (ASR-920-12SZ-IM)
NEBS1 ●  GR-63-CORE
●  GR-1089-CORE
●  SR-3580 NEBS Level 4
ETSI ●  ETS/EN 300 119 Part 4
●  ETS/EN 300 019 – Storage: Class 1.2, Transportation: Class 2.3, In-Use/Operational: Class 3.2
●  ETS/EN 300 753
Network synchronization ●  ANSI T1.101
●  GR-1244-CORE
●  GR-253-CORE
●  ITU-T G.703 clause 5
●  ITU-T G.703 clause 9
●  ITU-T G.781
●  ITU-T G.813
●  ITU-T G.823
●  ITU-T G.824
●  ITU-T G.8261/Y.1361
●  ITU-T G.8262
●  ITU-T G.8264
●  IEEE1588-2008
1 Notable exceptions: Fans do not have filters, and all cabling is provided through the front panel

 